archive-nz.com » NZ » B » BBRAUN.CO.NZ

Total: 448

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • B. Braun Melsungen AG - Products - Collagen Associated Chondrozyte Transplantation
    high quality support material Novocart Basic The patient s own cultured cells are distributed on a biphasic matrix and implanted in the defect via a min arthrotomy The biphasic structure of the matrix facilitates a verifiable uniform three dimensional distribution of the chondrocytes Novocart 3D is available in two dosage forms depending on the size of the defect Procedure Biopsy of the patient s own chondrocytes articular cartilage during an arthroscopy Culturing of the autologous chondrocytes from the primary culture in the TETEC AG special laboratory Reimplantation into the cartilage defect 3 weeks later via mini arthrotomy Cell cultivation of the highest quality Novocart 3D is individually produced for each patient and according to the latest advances in science and technology Cell culturing takes place in modern laboratories and cleanrooms The controlled certified procedure supports protection from infection All steps in the production of Novocart 3D take place in a standardized fashion and are continually monitored and documented No antibiotics or antimycotics are added Intended use Novocart 3D is used in autologous chondrocyte transplantation ACT for surgical treatment of full thickness limited local articular cartilage damages It is a two step procedure Advantages Tested and certified cell quality Extraordinary support material Special matrix achieves physiological cell distribution and simplifies implantation Minimally invasive surgical technique Fast and simple removal and reimplantation surgery Reliability in planning by implant delivery after exactly 3 weeks Validated logistics procedure Choice of fixation methods for the matrix Indication Chondral and osteochondral lesions of grade III IV ICRS Classification for larger defects of up to 14cm² in defect size up to 7 mm in defect depth Focal traumatic defects Osteochondrosis dissecans Osteochondral lesions associated with bone transplantation Note More information on the product manufacturing procedure surgical technique indications exclusion criteria postoperative care reimbursement of costs model Germany

    Original URL path: http://www.bbraun.co.nz/cps/rde/xchg/cw-bbraun-en-nz/hs.xsl/products.html?id=00020744610000000238&prid=PRID00007894 (2016-05-02)
    Open archived version from archive


  • B. Braun Melsungen AG - Products - Hydrogel Based Chondrozyte Transplantation
    Closure Home Products Orthopaedics Sports Medicine Hydrogel Based Chondrozyte Transplantation Hydrogel Based Chondrozyte Transplantation Novocart Inject Innovative hydrogel for arthroscopic autologous cartilage reconstruction Description Novocart Inject is an injectable albumin hyaluronic acid gel for autologous chondrocyte transplantation similar to the 3D This gel combines the patient s cultured autologous chondrocytes with an in situ polymerizing hydrogel It can then be injected arthroscopically into the damaged cartilage Procedure Biopsie of the patient s own chondrocytes articular cartilage during an arthroscopy Culturing of the autologous chondrocytes from the primary culture in the TETEC special laboratory Preparing the chondrocyte enriched gel and transplantation Stabilizes the chondrogenic phenotype The human chondrocytes in Novocart Inject show a high vitality and a stable chondrogenic phenotype in the polymerized biomaterial Intended use Novocart Inject is used in autologous chondrocyte transplantation ACT for surgical treatment of full thickness limited local articular cartilage damages and is particularly suitable for difficult to access areas Advantages Particularly suitable for difficult to access defect localizations and for uniform distribution of chondrocytes in the defect area by special vortexers Reliability in planning thanks to defined manufacturing duration of 3 weeks Stabilizes the chondrogenic phenotype Anti angiogenic and anti osteogenic Inhibits inflammation Resorbes without residues Quality certificate for each individual preparation Indication Chondral and osteochondral lesions of grade III IV ICRS Classification for defects up to 14cm² and up to 7 mm in defect depth Focal traumatic defects Osteochondrosis dissecans Osteochondral lesions associated with bone transplantation Note More information on the product manufacturing procedure surgical technique indications exclusion criteria postoperative care reimbursement of costs model Germany only references and ordering information are found in our brochure Scientific cooperation Our partner is TETEC AG a subsidiary of B Braun Aesculap AG TETEC is managed by doctors and biologists and is authorized to manufacture autologous chondrocyte

    Original URL path: http://www.bbraun.co.nz/cps/rde/xchg/cw-bbraun-en-nz/hs.xsl/products.html?id=00020744610000000238&prid=PRID00007896 (2016-05-02)
    Open archived version from archive

  • B. Braun Melsungen AG - Products - Art(h)cut Punches
    Therapy IV Drugs Neurosurgery Orthopaedics Other Products Regional Anesthesia Skin and Wound Management Spine Stoma Care Surgical Technologies Vascular Diagnosis and Therapy Wound Closure Home Products Orthopaedics Sports Medicine Art h cut Punches Art h cut Punches The innovative instrument line for arthroscopy Description Minimal cutting force and precise cut due to a patented jaw technology Simple detachable instruments for a superior cleaning and therefore safety for patient and surgeon

    Original URL path: http://www.bbraun.co.nz/cps/rde/xchg/cw-bbraun-en-nz/hs.xsl/products.html?id=00020744610000000238&prid=PRID00005409 (2016-05-02)
    Open archived version from archive

  • B. Braun Melsungen AG - Products - Proximal Humerus / Targon® PH
    Regional Anesthesia Skin and Wound Management Spine Stoma Care Surgical Technologies Vascular Diagnosis and Therapy Wound Closure Home Products Orthopaedics Trauma Proximal Humerus Targon PH Proximal Humerus Targon PH Intramedullary nail system for the proximal humerus Description The blood supply to the capitellar fragments provided by the fine branches of the circumflex humeral artery can be damaged by surface compression e g by a T plate and by the constricting

    Original URL path: http://www.bbraun.co.nz/cps/rde/xchg/cw-bbraun-en-nz/hs.xsl/products.html?id=00020744610000000239&prid=PRID00002330 (2016-05-02)
    Open archived version from archive

  • B. Braun Melsungen AG - Products - Humerus / Targon® H
    Home Products Orthopaedics Trauma Humerus Targon H Humerus Targon H Intramedullary nail system for humeral shaft fractures Description The selection of a suitable surgical approach is not just a question of the surgeon s personal preference The obvious advantage of retrograde nail implantation is the extraarticular access On the other hand the retrograde approach becomes more and more problematic e g risk of fracture of the bone bridge between the

    Original URL path: http://www.bbraun.co.nz/cps/rde/xchg/cw-bbraun-en-nz/hs.xsl/products.html?id=00020744610000000239&prid=PRID00002323 (2016-05-02)
    Open archived version from archive

  • B. Braun Melsungen AG - Products - Femoral Neck / Targon® FN
    Zealand Vacancies Product Overview Orthopaedics Hip Arthroplasty Knee Arthroplasty Power Systems Navigation Sports Medicine Trauma Product QuickFinder Continence Care Urology Diabetes Care Infection Prevention Infusion Therapy IV Drugs Neurosurgery Orthopaedics Other Products Regional Anesthesia Skin and Wound Management Spine Stoma Care Surgical Technologies Vascular Diagnosis and Therapy Wound Closure Home Products Orthopaedics Trauma Femoral Neck Targon FN Femoral Neck Targon FN Head preserving solution for medial and lateral femoral neck fractures Description The Targon FN TeleScrews allow a controlled collapse of the fracture along the line of the femoral neck without any backing out of the screws into the soft tissues Linking these distal and proximal screws with a locking plate gives a much more stable construction with superior rotational stability than would be found with either method of fixation alone Specific instruments have been designed to make the procedure easier to undertake using minimally invasive surgery The surgical technique allows the surgeon to achieve an easy optimum fixation and at the same time avoid potential complications such as bending of the guide wires or pushing of the guide wires into the pelvis The initial positive experience with the Targon FN suggests this implant may be a major advance in

    Original URL path: http://www.bbraun.co.nz/cps/rde/xchg/cw-bbraun-en-nz/hs.xsl/products.html?id=00020744610000000239&prid=PRID00004542 (2016-05-02)
    Open archived version from archive

  • B. Braun Melsungen AG - Products - Proximal Femur / Targon® PFT
    New Zealand Vacancies Product Overview Orthopaedics Hip Arthroplasty Knee Arthroplasty Power Systems Navigation Sports Medicine Trauma Product QuickFinder Continence Care Urology Diabetes Care Infection Prevention Infusion Therapy IV Drugs Neurosurgery Orthopaedics Other Products Regional Anesthesia Skin and Wound Management Spine Stoma Care Surgical Technologies Vascular Diagnosis and Therapy Wound Closure Home Products Orthopaedics Trauma Proximal Femur Targon PFT Proximal Femur Targon PFT Intramedullary nail system for proximal femoral fractures Description The new Targon PFT nailing system is designed to treat all trochanteric fractures in a fast and safe procedure The innovative targeting device is suitable for all CCD angles and permits shorter and less invasive incisions thanks to an optimized geometry The color code of the instruments guides you reliably through the operation and the simplified instrumentation leads to a substantially reduced operating time The Targon PFT telescoping cantilever ensures an effective sliding of the fracture The merger of sleeve and lag screw into the new TeleScrew facilitates the insertion and shortens the operating time Cranial migration of the TeleScrew is ruled out by the integrated distraction stop Laterally the TeleScrew is locked angle stable to the nail which prevents backing out The new TeleScrew thread provides an enlarged contact

    Original URL path: http://www.bbraun.co.nz/cps/rde/xchg/cw-bbraun-en-nz/hs.xsl/products.html?id=00020744610000000239&prid=PRID00005391 (2016-05-02)
    Open archived version from archive

  • B. Braun Melsungen AG - Products - Distal Femur / Targon® RF
    Technologies Vascular Diagnosis and Therapy Wound Closure Home Products Orthopaedics Trauma Distal Femur Targon RF Distal Femur Targon RF Retrograde femoral nail Description The distribution of reaming debris in the knee joint is avoided by opening the joint with the hollow reamer Sufficiently recessed placement of the implant prevents protruding implant edges As a result of the ventral and dorsal oblique surfaces of the Targon RF the nail recess can

    Original URL path: http://www.bbraun.co.nz/cps/rde/xchg/cw-bbraun-en-nz/hs.xsl/products.html?id=00020744610000000239&prid=PRID00002376 (2016-05-02)
    Open archived version from archive



  •